Test Directory

Test Code
HBSQN
Test Name
Hepatitis B Surface Antigen, Quantitative, Monitoring (Not for Diagnosis)
CPT Codes
87467
Expected Turnaround Time
2 - 4 days
Clinical Utility

Quantitative measurement of HBsAg may be used to confirm ongoing HBV replication and monitor responses to antiviral therapy. Published studies support the viewpoint that repeatedly low to undetectable HBsAg values are a good predictor of sustained viral clearance. This test should be used on individuals previously diagnosed with hepatitis B infection by qualitative HBsAg testing.

Specimen and Container Info

Specimen Type: Serum

Preferred Collection Container: Red Top, Plain

Alternate Collection Container: Gold Top, Serum Separator

Desired Specimen Volume: 2 mL

Collection Instructions
  1. Collect a red top, plain tube via venipuncture.
Processing and Submission Instructions
  1. Separate serum from cells.
  2. Transfer 2 mL of serum to a clear aliquot tube (screw cap).
Transport Instructions

Transport to the laboratory refrigerated.

Stability Requirements

Room Temperature

7 days

Refrigerated

14 days

Frozen

30 days

Causes for Rejection
  • Gross hemolysis
  • Grossly lipemic
Methodology
Immunometric Immunoassay
Reference Intervals

See patient report.

Limitations

Quantitative HBsAg testing is not recommended for initial diagnosis but is useful for disease and treatment monitoring and management of patients with chronic hepatitis B infection

Alternate Names
  • HBsAg Quantitative (Monitoring not for dx)
Reference Lab
Quest Diagnostics Nichols Institute
Testing Schedule
Routine, Monday - Saturday