Test Directory
| Test Code | ||
| INSIT | ||
| Test Name | ||
| InSight® FISH | ||
| CPT Codes | ||
| 88271 X 5, 88275 | ||
| Expected Turnaround Time | ||
| 2 - 3 days | ||
| Clinical Utility | ||
|
This test is used for fluorescence in situ hybridization (FISH) and prenatal aneuploid evaluation FISH targeting numerical changes in 13, 18, 21, X, Y. If specimen volume is too small, then direct FISH may not be performed and results may be obtained if cultured chromosome studies are ordered. |
||
| Specimen and Container Info | ||
|
Specimen Type: Amniotic Fluid
Collection Container: Sterile, Non-additive Container Desired Specimen Volume: 5 mL |
||
| Collection Instructions | ||
|
||
| Processing and Submission Instructions | ||
|
||
| Transport Instructions | ||
|
Transport to the laboratory refrigerated. |
||
| Stability Requirements | ||
|
||
| Causes for Rejection | ||
|
||
| Methodology | ||
| Fluorescence in situ hybridization (FISH) | ||
| Reference Intervals | ||
|
See patient report. |
||
| Limitations | ||
|
Molecular mutations below the resolution of FISH will not be detected; will not detect aneuploidy that is not targeted by FISH probes in this panel. |
||
| Reference Lab | ||