Test Directory

Test Code
LIDO
Test Name
Lidocaine
CPT Codes
80176
Expected Turnaround Time
Same day
Clinical Utility

Useful for assessing therapeutic levels and potential toxicity.

Specimen and Container Info

Preferred Specimen Type: Serum

Preferred Collection Container: Red Top, Plain  

Desired Specimen Volume: 1 mL  

Collection Instructions
  • Collect specimens 12 hours after initiating therapy for arrhythmia prophylaxis, then every 24 hours thereafter.
  • Obtain specimens every 12 hours when cardiac or hepatic insufficiency exists.
Transport Instructions

Transport to the laboratory refrigerated. 

Causes for Rejection

Specimens collected in separator tubes will be rejected.  

Methodology
Enzyme Immunoassay (EIA)
Reference Intervals

Age

Reference Interval

Units

All Ages

1.5 - 5.0

µg/mL 

Critical Values

Age

Critical Range

Units

All Ages

>=5.1

µg/mL 

 

Performing Location
Roble Road Core Laboratory
Alternate Names
Xylocaine
Testing Schedule
Routine daily, STAT testing available